STE S Type Alloy Steel Load Cell For Hopper Scales
Short Description:
Our hopper scales use the STE S Type Alloy Steel Load Cell for accurate, reliable weighing. Built for heavy loads, these tough load cells provide accurate measurements in factories. Ideal for manufacturing, construction, and shipping, they combine strength with ease of use. Contact us to learn more or place an order!
Features:
Load Cell Range: 300kg
Two-way force measurement, tension and compression
Simple structure, easy to install
High overall accuracy, good long-term stability
Aluminum alloy material, anodized surface
Protection level IP65
Applications:
Hook scale, crane scale
Hopper scale, tank scale
Tension and pressure measurement
Description:
STE uses a special hook shape. This design works well with hook scales. STE is a tension and compression weighing force sensor. It’s made of aluminum alloy and has a glue-sealed, anodized surface. This design ensures high accuracy and long-term stability.
Dimensions:

| Specification | ||
| Specification | Value | Unit |
| Rated load | 300 | kg |
| Rated output | 1.2±0.005 | mV/V |
| Zero balance | ±1 | %R.O. |
| Comprehensive Error | ±1 | %R.O. |
| Zero balance | ±0.02 | %R.O. |
| Repeatability | ±0.05 | %R.O. |
| Hysteresis | ±0.1 | %R.O. |
| Return to zero | ±0.05 | %R.O. |
| Creep (after 30 minutes) | ±0.05 | %R.O. |
| Normal operating temperature range | -10~+40 | ℃ |
| Allowable operating temperature range | -20~+70 | ℃ |
| Effect of temperature on zero point | ±0.05 | %R.O./10℃ |
| Effect of temperature on sensitivity | ±0.05 | %R.O./10℃ |
| Recommended excitation voltage | 10 | VDC |
| Input impedance | 380±5 | Ω |
| Output impedance | 350±3 | Ω |
| Insulation Resistance | ≥5000(50VDC) | MΩ |
| Safe overload | 150 | %R.C. |
| Limit overload | 400 | %R.C. |
| Material | Alloy steel | |
| Protection Class | IP67 | |
| Cable length | 3 | m |